1. Professional high current wiring design & workmanship, thus can withstand the shock of high current
2. Using fully enclosed heat-dissipating glue and a double-sided heat dissipation design, heat is dissipated in time, and the heat dissipation effect is better than others.
3. Dustproof, shockproof, anti-squeezing, and other protective functions
4. Complete overcharge, over-discharge, over current, short circuit, and equalization functions
(4S 200A-250A)
No |
Description |
Specification |
Remarks |
||
1 |
Discharge |
Continue discharge current |
200A |
250A |
|
2 |
Charge |
Charge voltage |
14.6V |
|
|
Charge current |
100A |
125A |
|
||
3 |
Over charge protection |
Over charge detect voltage |
3.75±0.05V |
|
|
Over charge protection delay |
1S |
|
|||
Over charge release voltage |
3.65±0.05V |
|
|||
4 |
Balance |
Balance detect voltage |
3.2V |
|
|
Balance current |
30±5mA |
|
|||
Balance opening condition |
1. On a charge 2. Achieve balance detect voltage 3. Achieve 50mv |
||||
5 |
Over discharge protection |
Over discharge detect |
2.2±0.01V |
|
|
Over discharge detect delay |
1S |
|
|||
Over discharge release voltage |
2.3±0.01V |
|
|||
6 |
Charging over current protection |
Charging over current protection current |
300±30A |
375±38A |
|
Over Charge current detect delay |
1S |
|
|||
Over Charge current protection release condition |
Off load |
|
|||
7 |
Discharge over current protection |
Discharge over current protection current |
300±30A |
375±38A |
Can set as required |
Over discharge current detect delay |
1S |
Can set as required |
|||
Over discharge current protection release condition |
Off load |
||||
8 |
|
Short Circuit protection condition |
Short circuit of external load |
||
Short circuit detect delay |
320uS |
|
|||
Short circuit protection release |
Off load |
||||
9 |
Temp Protect |
Charge Temperature protection degrees |
-40~65℃ |
Recover-35℃ Recover 60℃ |
|
discharge Temperature protection degrees |
-40~70℃ |
Recover-35℃ Recover 65℃ |
|||
Release Condition of temperature protection |
Recovery temperature reached and load disconnected |
||||
10 |
Means of communication |
UART/ BT/CAN/RS485 Customization Option |
|||
11 |
Inner Resistance |
Main Circuit Conduct Inner resistance |
<20mΩ |
|
|
12 |
Self Consumption |
Working current |
20mA |
|
|
Sleeping current |
800uA |
|
|||
13 |
Working Temp |
Temp range |
-20~70℃ |
|
|
14 |
Storing Temp1 |
Temp range |
-40~80℃ |
|