deye battery50kw/60kwh all in one ESS




  • Rated power operation the maximum temperature of the battery is less than 40℃
  • EMS,hybrid inverter and BMS integrated technology, power supply redundancy design, support black start function,Off grid operation, etc
  • Suitable for high rate cyclic charging and discharging scenarios
  • Lithium Iron Phosphate (LFP) Battery, The battery pack and system adopt an aerosol fire extinguishing solution 
  • Combustible gas, smoke and temperature detection, system active exhaust, and fire alarm
  • Supports battery expansion, with a maximum capacity of 360KWh






Specifications


Model

GE-F60

System Specification

Model

GE-F60-V1

AC Output Frequency and Voltage

50/60Hz; 3L/N/PE 220/380, 230/400Vac

Grid Type

Three phase

Energy Configuration (kWh)

61.4

Dimension (W x D x H,mm)

735x1050x2250no contain inverter

Weight Appr. (kg)

950battery+80inverter

AC Output Rated Current (A)

75.8

Battery Operating Voltage (V)

500 ~ 700

Max. charging/discharging efficiency

91%

Battery Chemistry

LiFePO4

IP Rating of Enclosure

IP55

Installation Style

Floor-Mounted

Warranty

10 years

Inverter Technical Specification

Max. PV Input Power (W)

65000

Max. PV Input Current (A)

36+36+36+36

Rated PV Input Voltage (Vdc)

600

Start Up DC Voltage (Vdc)

180

MPPT Voltage Range (Vdc)

150-850

Max. PV Short-circuit Current (A)

55+55+55+55

Number of MPPT

4

Peak Power (off grid)

1.5 time of rated power, 10s

Power Factor

0.8 leading to 0.8 lagging

THD

<3%

DC injection current (mA)

<0.5%ln

Display

LCD

Operating Temperature Range (℃)

-40~60( >45℃ derating)

Relative Humidity

15% ~ 85% (No Condensing)

Dimension (W x D x H,mm)

527x294x894

Inverter Communication

CAN,RS485,WIFI,ETH

Max. Efficiency

97.6%

MPPT Efficiency

99.9%

Battery Technical Specification

Battery Module Nominal Voltage (V)

51.2

Battery Module Energy (kWh)

5.12

BMS Communication

CAN

Battery Module Dimension(W*D*H mm)

440x570x133

Battery Module Weight (kg)

44

Operating Temperature Range

Charge: 055℃ / Discharge: -20℃55℃

Cycle Life

≥6000(@25℃±2℃,0.5C/0.5C,70%EOL)

Battery Module Certification

CE, IEC62619, IEC62040, UN38.3


Safety EMC / Standard: IEC/EN 62109-1,IEC/EN 62109-2,IEC/EN 61000-6-1, IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4

Grid Regulation: VDE4105,IEC61727/62116,VDE0126,AS4777.2,CEI0 21,EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/ NBR16150




Product expansion




Product expansion


Product introduce



details-1


①Air conditioner

Cooling the ESS system

②Smoke detector

A device used to detect smoke in a fire and

sound an alarm when smoke is detected.

③Heat detector

A device used to measure temperature and

sound an alarm if it detects excessive

temperature.

④Travel switch

Check whether the ESS system door is closed.

⑤Inverter

A device that converts direct current

generated by a battery into alternating

current.

⑥Aerosol fire extinguishing device

When the ESS is detected to be on fire,

aerosol is emitted to extinguish the fire.


details-2


Fan

Emission of combustible gas

Combustible gas sensor

Detect combustible gases

Serial relay

Control system

Terminal line

For connecting cables

Switching Mode Power Supply

Power source

Temperature and humidity sensor

Used to measure ambient temperature and humidity

Miniature circuit breaker

Controlled power-on and power-off

Relay

Automatic regulation, safety protection, conversion circuit

Water immersion sensor

Check the ESS for water leakage

Terminal line

Connect external cables



details-3



①Aerosol fire extinguishing device

When the pack is detected to be on fire, aerosol is

emitted to extinguish the fire

②Battery module

Provides electrical energy storage and output

③CCS

Cells Contact System

④Air inlet

Cold air inlet

⑤Battery negative-

/

⑥Battery positive+

/

⑦Fan

Promote internal and external air flow

⑧BMU

Battery monitoring




details-4


B-

Connection position of the common negative pole of the battery

B+

Connection position of the common positive pole of the battery

Air switch

Used to manually control the connection between the battery rack and external devices

ALRM light indicator

Battery system fault alarm indicator

HV light indicator

High-voltage hazard indicator

PCS-

Connection position of PCS negative pole

PCS+

Connection position of PCS positive pole

USB

BMS upgrade interface and storage expansion interface

OUT COM

Connection position with next HVB-100A 750V communication output

IN COM

Connection position with previous HVB-100A750V communication input

PCS COM

Communication interface with charging and discharging equipment

START

A start switch of 12VDC power inside the high-voltage control box

COMM1

Communicative connection with the cabinet

COMM2

Communicative connection with the first battery module;

and providing 12VDC power for the first battery module.