Model |
EVL6125 |
EVL6115 |
EVL6116 |
EVL6138 |
DC Voltage |
24V |
48V |
80V |
120V |
Rated Current |
500A |
250A |
150A |
125A |
Current Range |
1-500A |
1-250A |
1-150A |
1-125A |
Range of Output Voltage |
18-30V |
38-60V |
65-100V |
92-132V |
Input Voltage |
380V±10% |
380V±10% |
380V±10% |
380V±10% |
Input Current |
30A |
|||
Output Power |
15KW |
|||
Input Mode |
L1+L2+L3+PE three-phase four wire system/L1+L2+L3+N+PE three-phase five wire system |
|||
Power Factor |
>0.99 |
|||
THD |
<10% |
|||
Efficiency |
>95% |
|||
Current Ripple |
±3% |
|||
Current Precision |
±0.5% |
|||
Voltage Precision |
±0.5% |
|||
Ripple Voltage |
≤±1%Vo peak-to-peak value,20Mhz bandwidth, |
|||
Charging Precision |
Voltage/0.01V Current/0.1A Time/1S |
|||
BMS Power Supply |
12V/24V Optional |
|||
Protection Function |
OTP、OVP、OCP、Short |
|||
Connector |
Anderson/International charging gun/REMA/The customer agreement |
|||
Communication Method |
RS485、RS232、CAN Bus |
|||
MTBF |
80000H |
|||
Safety |
CE、UL1564,IEC61851 |
|||
Display |
LCD/LED |
|||
Cooling |
Air Fan |
|||
Working/Storage temperature and humidity |
Working: -20℃ to 65℃ Storage:-40℃ to 85℃ |