Welcome To Evlithium
Best Store For Lithium Iron Phosphate (LiFePO4) Battery
lithium battery supplier
Home > Hot Product>3.2V 125ah high discharge rate lithium lifepo4 prismatic power cells

3.2V 125ah high discharge rate lithium lifepo4 prismatic power cells

Hot Product
3.2V 125ah high discharge rate lithium lifepo4 prismatic power cells for for Commercial vehicles, heavy trucks, light trucks
Description

Features

Automated

Automated production / Prodcut consistency

Ultra-Safe

Explosion-proof / No leakage

Stable

Low IR / High CR / Discharge Steadily

Customized Custom-made

Customer Demand Customization

Super Long

Ultra-long life cycle

Environmentally Friendly

Passed environmental system certification

 

Specifications

 

Specification Parameters

Nominal Capacity

125Ah

Nominal Voltage

3.22V

Initial IR

0.40 mΩ ± 0.05 mΩ

Weight

2390 g ± 71 g

Charging Cut-off Voltage

3.65 V

Discharging Cut-off Voltage

2.5 V T > 0¡æ) 2.0 V T ≤ 0¡æ)

Charging Temperature

- 10 ¡æ~65¡æ

Discharging Temperature

- 35¡æ~65¡æ

Storage Temperature

-20¡æ ~ 45¡æ

Model Name

LF125

Cycle Life

4000 Cycles

Standard Charging Current

62.5 A

Standard Discharging Current

62.5 A

Height(H) with terminal

172.00 mm ± 0.50 mm

Height(h) without terminal

169.30 mm ± 0.50 mm

Length

200.70 mm ± 0.50 mm

Thickness

33.25 mm ± 0.50 mm

 

Details

details of eve lf125 125ah lifepo4 cell

dimensions

high discharge rate power battery cell

Applications

 

eve lf125 125ah lifepo4 cell

bulldozers, heavey truck, forlift, buses, and passenger cars

 

Transportation and Handling Requirements

 

  • It is not allowed to ship with inflammable, explosive and corrosive articles in the same vehicle during transportation, and stacking is prohibited during large package transportation; The product shall not be exposed to rain, snow and other liquid substances without any protection, or suffer mechanical damage;
  • While handling, lift trucks or special tools shall be used to load and unload products; Handle with care, do not throw or squeeze, which may cause cell damage or personal injury. It is strictly prohibited to put cells together with  corrosive substances such as acid and alkali.

 

Operation Precautions 

  • It is strictly forbidden to immerse the cell in water. When it is not in use, it should be placed in a cool and dry environment.
  • Do not overcharge the cell. Otherwise, cell overheating and fire may occur. During cell installation and use, hardware and software must be protected against multiple overcharge failures. See 4.3 of this specification for the minimum requirements of protection.
  • It’s necessary to set a reasonable charging time limit, otherwise, the cell may overheat, resulting in thermal runaway or fire. BMS management failure of this kind shall be considered during module design.
  • If improper charge termination occurs, the root reasons shall be found and resolved before reuse to avoid negative effects on electrical and safety performances.
  • It is forbidden to over-discharge. During the normal use of the cell, charge the cell regularly to keep the voltage above 2.8 V, so as to avoid over-discharge.
  • The temperature of the cell shall not exceed 60¡æ in any normal use, otherwise the BMS must shut down the cell and stop cell operation.
  • Please use a special charger for lithium-ion batteries when charging
  • During use, please connect the positive and the negative of the cell strictly according to the labels and instructions, and reverse charging is forbidden.
  • It is forbidden to use metal to directly connect the positive and the negative of the cell to short-circuit. Otherwise, strong current and high temperature may cause personal injury or fire.
  • It is forbidden to transport or store the cell with metal, such as hairpins, necklaces, etc.
  • It is forbidden to knock, throw, step on or bend the cell.
  • It is forbidden to directly weld the cell or pierce the cell with nails or other sharp objects
  • Try to protect the cell from mechanical shock, collision and pressure impact. Otherwise, the cell may be short-circuited internally, resulting in high temperature and fire.
  • It is forbidden to use or place the cell at a high temperature environment (under direct-sunlight). Otherwise, cell overheat, function failure or life shorten may occur.
  • It is forbidden to use it in places with strong static electricity and strong magnetic fields; otherwise cell safety protection devices may be damaged and cause safety hazards.
  • Customer shall securely fix the cell to a solid surface and bind the power cord in a proper place to avoid arcing and sparks caused by friction.
  • It is forbidden to use plastic for cell encapsulation and electrical connection. Improper electrical connection may cause overheat during cell use.
  • If the cell leaks and the electrolyte spills onto the skin or clothes, immediately wash the affected area with running water. If the cell leaks and the electrolyte enters the eyes, mouth, nose and other open parts of the human body, immediately wash with plenty of water and seek medical treatment immediately, otherwise serious injuries will be caused to the human body. No person or animal is allowed to swallow any part of the cell or any substance contained in the cell.
  • If the cell emits peculiar smell, heat, discoloration, deformation, or any abnormality during use, storage, or charging, immediately remove the cell from the device or charger and stop using it.


Contact us
Homepage
Fold