Items |
Parameters |
Battery Type |
LiFePO4 Pouch Cell |
Rated Capacity (Ah@0.5CP) |
100 |
Rated Energy (Wh@0.5CP) |
320 |
Rated voltage(V) |
3.2 |
Rated charge and discharge power (W) |
160W (0.5CP)
|
Maximum continuous charge and discharge power (W) |
320W(1.0CP) |
Operating temperature (⊥) |
Chargeㄩ-10~55; Dischargeㄩ-20~55 |
Size(mm) |
T22.5*W122.7*L360.5mm |
Weight(g) |
1890 |
RTE (0.5CP/0.5CP) |
≡94%
|
Cycle life(@0.5C) |
6000@80%SOH |
Design life (years) |
10
|
Authenticate |
GBT36276/UL9540A/IEC62619 /UL1973/UN38.3 |
Security Design
Module short circuit protection
Maintenance Convenience Design
Concise Interface Design
Hidden wiring harness design
Compatibility Design
Module 3U, suitable for 19-inch cabinet
Electrical selection compatible with 1000-1500V
Items |
Specifications |
Cell Type |
LFP, 100Ah |
Connection |
2 parallel 16 series (2P16S) |
Total Capacity/ Energy |
200Ah/10.24kWh |
Usable/Capacity/Energy |
196Ah/10kWh |
Nominal Voltage |
51.2V |
Output Voltage Range |
44.8~57.6V |
Max. Charge/Discharge Power |
5.12kW (0.5CP) |
Room Temperature Cycle Life (25⊥㊣2⊥) |
6000cycles @70%SOH |
Module Safety Certification |
IEC62619 /UL1973/UL9540A/GBT36276/RCM/CE EMC /FCC |
UN Transportation Test Standard |
UN38.3 |
Ingress Protection |
IP20 |
Operating ambient temperature |
-10⊥~50⊥
|
Optimal operating temperature |
15⊥~30⊥ |
Operating ambient humidity |
5%~95%, No condensation |
Storage conditions |
30% SOC; 7days @ㄗ -30~-20⊥ㄘ@ㄗ45~60⊥ㄘ5%~95RH˙ 6 months @ -20~45⊥ㄛ5%~95RH |
Dimensions |
W445*D913.2*H129 mm(without bracketㄘ
|
Altitude |
≒3000m |
Weight |
80kg |
Installation |
Rack-mounted installation |
Integrated Design
HVB (BMS Control Box) includes BCU, IVU, can support expandable BAMS, ESU, and also adds 24VDC, which can support black start.
Maintenance Convenience Design
Modular PCBA design with convenient expansion for level 2 and 3 (BAMS/ESU).
Hot plug design, PCBA convenience maintenance.
Safety/Reliability Design
Electronics/electrical components are easy to replace, 24VDC dual power backup, improving system reliability.
Insulation detection, loose connection detection.
Compatibility Design
Module 3U, suitable for 19-inch cabinet
Electrical selection compatible with 1000-1500V
Items |
Parameters |
Model |
C-H1500100SA1 |
Max. Operating Voltage Range |
Max. 1500V DC |
Max. Input / Output current |
120A |
Optimal operating temperature |
15⊥~30⊥ |
Environment temperature range |
-10⊥~50⊥
|
Communication between HV-BOX and PCS or DC/DC |
CAN & RS485 & Ethernet (three ports)
|
Max. Module Serial Connect |
26S |
Dimensions |
W442*D500*H217.2 mm |
Weight |
26kg |
Ingress Protection |
IP20 |
Items |
Parameters |
Total capacity |
400Ah |
Usable capacity |
392Ah |
Total energy |
532.4kWh |
Usable energy |
521.8kWh |
Nominal voltage |
1331.2V
|
Operating voltage range |
1164.8~1497.6 V
|
Max. Charge/Discharge power |
266.2kW (0.5CP) |
Room Temperature Cycle Life (25⊥㊣2⊥) |
6000cycles@70%SOH |
Room Temperature Calendar Life(25∼C㊣2⊥) |
10years |
Operating ambient temperature |
-30⊥~55⊥ |
Optimal operating temperature |
15⊥~30⊥
|
Operating ambient humidity |
5%~95%, No condensation |
RTE |
≡94% for fresh battery |
Discharge rate of Module |
≒2%/month/@25⊥ |
Module Series connection/Module |
26S |
Rack Parallel connection/Rack |
Max. 16 units in parallel (025CP)
|
Ingress Protection rate |
IP54/NEMA 3R
|
Cooling |
HVAC |
Dimension |
W2200mm*H2443mm*D1400mm |
Weight |
5800kg |
Altitude |
≒3000m |
Communication between PCS and battery system |
CAN & RS485 & Ethernet (three port) |
Regulation compliance |
IEC62619 /UL1973/GB/T 36276/RCM/CE EMC/FCC |
EMC standard |
EN61000-6-1&EN61000-6-3 |
UN Transportation Test Standard |
UN3841/Battery cabinet,UN38.3/PACK |
Environment protection standard |
RoHSㄛREACHㄛTSCAㄛbattery directive
|
Items |
Parameters |
Rated voltage |
1500V
|
Max. current (@25⊥) |
2*800A |
Peak current (@25⊥) |
2*944A@5s |
Number of connected battery cabinets |
Max. 16 battery cabinets for 0.25CP; 8 battery cabinets for 0.5CP; |
Communication port |
Ethernet( Eight portsㄘ |
Power interfaced to PCS |
2 positive and 2 negative portsㄛ6*朴13 |
Power interfaced to battery cabinets |
2 positive and 2 negative portsㄛ4*朴8 |
Distribution port from grid |
80Aㄛ480VAC(Configurable)ㄛ3P+N |
Distribution port to battery cabinets |
6*25A, 220VACㄛFor HVAC,P+N 6*25Aㄛ220VACㄛP+N |
2*10A, 220VACㄛFor BMS,P+N /BMSㄛ2*10Aㄛ220VACㄛP+N |
|
Dimensions (W*H*D) |
1800*2450*1000mm |
Weight |
1400kg |
Operating ambient temperature |
-30⊥~55⊥ |
Operating ambient humidity |
5%~95% |
Ingress Protection rate |
IP55 |
Cooling |
Air forced cooling |
Altitude |
≒3000m |