Individual pricing for large scale projects and wholesale demands is available.
Mobile/WhatsApp/Wechat: +86 156 0637 1958
Email: info@evlithium.com
We use standard chassis and containers that can flexibly match system energy according to customer needs. Our products cover energy storage systems, thermal management systems, fire protection systems, EMS systems, and inverter systems.
Features
Battery energy storage system specification
DC parameters |
||
Cell type |
Prismatic/3.2V 280Ah |
LiFePO4 Battery |
Nominal capacity |
2.365 MWh |
704V 280Ah*12 |
Voltage range |
638V~770V |
Cell: 2.8~3.55V |
Battery system efficiency |
≥98% |
Capacity efficiency |
Communication |
CAN, Modbus RTU |
|
AC parameters |
||
AC Rated Power |
500kWA *2 (2 in Parallel) |
|
AC Max. Power |
500kWA *2 (2 in Parallel) |
|
System efficiency |
≥88% |
|
Rated AC Voltage |
400V |
|
Grid voltage range |
±10% |
|
Power factor |
>0.99 |
|
Power factor adjustable range |
1 (lead) ~ 1 (lag) |
|
Rated frequency |
50 Hz/60 Hz |
|
Grid frequency range |
±20% |
|
AC current distortion rate |
<3% |
|
DC component
|
<0.5% |
|
EPS-AC |
Three-phase three-wire system + ground wire |
3W+PE |
System Parameters |
||
Operating temperature |
5~30¡æ |
Industrial temperature control air conditioning |
IP Grade |
IP54 |
|
Environment temperature |
-30¡æ~50¡æ |
|
RH |
0~95% |
|
Noise |
<70dB |
|
Man-machine interaction |
Touch LCD screen +EMS background |
|
Seismic grade |
¢÷ |
|
Communication |
RS485, Ethernet |
|
Communication protocol |
Modbus RTU, Modbus TCP |
|
Containers overall external dimensions |
40HQ/12.192*2.438*2.896m |
|
Containers internal dimensions |
40HQ/12.032*2.352*2.698 |
|